9 apr 2013 , hardie siding installation job by texas home exteriors. hardie siding installation job. stainless steel fasteners are recommended when installing james hardie products near the ocean, large bodies of water, or in very humid climates. the beauty of properly installing hardieplank siding will result in no,

6 oct 2015 , today, i rarely see james hardie siding used on new homes any more; builders are using lp smartside® instead. , common defect. here's a small collage of overdriven nails. overdriven nails. the diagram below shows the appropriate repair methods for overdriven nails. lp smartside nailing diagram,

lp smartside panel - lp building productslp does not recommend lp smartside panel for use in icf and. sip assemblies. , gutters are recommended for control of roof water run off. • all openings , trim. do not run trim or siding inside of the kick out flashing. 3/8 in. from edge. 1/8 in. gap. single row of nails. nail penetration min. 1-1/2 in. alignment bead. figure 2.

25 nov 2015 , using a nail gun makes quick work of installing lp smartside products. you will want to use a minimum of .113-inch shank diameter, hot-dipped, galvanized box-style nail with a minimum of .270-inch head diameter. the nails should be long enough to penetrate the structural framing by at least 1-1/2 inches,

29 jun 2015 , contractors, watch this video to learn which types of nails and wood screws can be used when installing lp smartside lap siding and how your choice of fastener affects spacing requirements. also refer to the detailed product application instructions at www.lpsmartsideSevenTrust.

25 nov 2011 , screw heads need to be sunk in enough so that they can be covered with a protective compound and painted over, making them disappear. a professional-grade screw gun for decks work well in applying the t1-11 to the studs. whether nails or screws, it is important to use galvanized or stainless steel,

frequently asked questions - bluelinxrecommended. refer to the installation instructions for proper installation. 15. how do i install smartside siding® over sip or icf assemblies? a. follow the lp smartside installation instructions. the sip manufacturer will need to specify the type of corrosion resistant fastener and the fastener spacing to meet the minimum,

lp smartsidemanner that prevents moisture intrusion and water buildup. • in non-traditional icf and sip assemblies, the icf or sip manu- facturer must prescribe the fastening specifications. note: lp does not recommend lp smartside for use in these non-tradi- tional assemblies. if used, lp will not warrant for buckling and. shrinkage.

688-n75c-1 features: -type of nailer:siding nailers -type of fastener:siding nails -type of fastener:nail coils -fastener size range:1.25" - 2.5". ,. i sided a two story 1300 square foot garage using lp smartside. ,. see and discover other items: bostitch hand tools, best rated in power siding nailers, siding nailers.

8 oct 2013 , learn how lp siding has replaced t1-11 as the best choice for a wood shed. while t1-11 , however, lp® smartside siding is actually more natural than it may initially appear. it is still pure , when installing the lp primed smartside siding on a shed, should it be installed using nails or screws? where,

we had hoped to use 1.5 to 2 inches of eps rigid foam to the exterior of the sheathing, then 3/4 inch x 4 inch plywood furring strips, then lp smartside lap siding. we knew , (however, their instructions also seem to indicate that you need 16 inch centers if fastening to furring strips over foam. the rep told,

important: much of the strength and stability of the shed comes through the lp smart side panels. however they are osb and only 3/8″ thick so it is important to use a good glue like pl premium as noted in the videos (lp smart side panels are also available in 5/8″ via special order). in addition, if you plan to use the,

finish the siding with trim molding, typically 1-by-4-inch boards, around doors and windows and on corners. put 1-by-4 boards, quarter-round or other molding along the tops of the wall panels and along the bottom to cover the ledger boards. install batten boards over panel joints for that style of siding. use finishing nails for,

lp smartside trim & fascia - lp building productslp smartside trim and fascia can be applied directly over materials such as siding, or fastened directly to structural members up to 24 , tipped blade is recommended. ,. of 3 nails per width. for trim over 12 inches wide use a minimum of 4 nails per width. • where edges of trim meet siding material, windows, doors or.

application instructions - the SevenTrustlp smartside trim and fascia can be applied directly over materials such as siding, or , do not use staples. moisture. • moisture control and moisture vapor control are critical elements of proper housing design. check your local building codes for application , recommended, as it will leave the edges unprotected. if the.

if i were building a new home i would definitely use smartside over any fibercement board product. the fibercement is very fragile in its , it is good to once again not to have to be so careful about overdriven nails as it is a lot tougher product that does not allow this problem so readily. there are a lot of other,

sheet panel siding is an affordable option for covering a home's exterior. these products have gotten a bad reputation in recent years due to reports of panels that buckle, delaminate, or come loose from the wall. but if you choose the panels and fasteners carefully and follow correct installation procedures, plywood panels,

10 jul 2017 , he plans on installing 3/4-inch thick plywood furring strips on top of the exterior foam, and then will side the house with lp smartside lap siding designed specifically for , finally, he says, don't use the extra-long siding fasteners with the 1x4 furring unless you are able to get the ok from the manufacturer.

application instructions - lp building productslp smartside 76 series lap siding may be attached directly to , formulated for use on wood and engineered wood substrates, is highly recommended. , 1 in. overlap. self-aligning rabbet. install smartlock lap siding consistent with the specifications in these installation instructions. smartlock overlap & blind fastening,

lp smartside installation instructions - texas inspectormanufacturer must prescribe the fastening specifications. note: lp does not recommend lp smartside for use in these non-traditional assemblies. if used, lp will not warrant for. buckling and , ness to accept the full length of the recommended nail. secondary weather resistant barrier. • a properly installed breathable,